- universal AC input / full range (up to 305 VAC)
- built-in active PFC function
- protections: short-circuit / overload / overvoltage / overheating
- cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- suitable for LED lighting and moving sign applications
- IP67 design for indoor or outdoor installations
- in compliance with worldwide safety regulations for lighting
- suitable for dry / damp / wet locations
- constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance
- 5 years warranty
- for professional use only
- This device must be installed by a qualified person.
Specifications
- output:
- DC voltage: 24 V
- constant current region (Note 4): 12 V to 24 V
- rated current: 13.34 A
- rated power: 320.2 W
- ripple & noise (max.) (Note 2): 150 mVp-p
- voltage adj. range (Note 6): 21 V to 26 V
- current adj. range:
- can be adjusted by internal potentiometer or through output cable
- 6.67 A to 13.34 A
- voltage tolerance (Note 3): ± 1.0 %
- line regulation: ± 0.5 %
- load regulation (Note 8): ± 0.5 %
- setup, rise time (Note 9): 2500 ms, 80 ms at full load 230 VAC / 115 VAC
- hold-up time (typ.): 15 ms at full load 230 VAC / 115 VAC
- input:
- voltage range: 90-305 VAC 127-431 VDC
- frequency range: 47 to 63 Hz
- power factor: PF ≥ 0.95 / 230 VAC PF ≥ 0.98 / 115 VAC at full load and rated output voltage PF ≥ 0.9 at 50 to 100 % load
- efficiency (typ.) (230 VAC): 94 %
- efficiency (typ.) (277 VAC): 94.5 %
- AC current: 3.5 A / 115 VAC 1.65 A / 230 VAC 1.45A / 277VAC
- inrush current (typ.): cold start 75 A / 230 VAC
- leakage current: < 0.75 mA / 277 VAC
- protection:
- overcurrent (Note 4):
- 95 to 108 %
- protection type (overcurrent (Note 4)): constant current limiting, recovers automatically after fault condition is removed
- short-circuit: hiccup mode, recovers automatically after fault condition is removed
- overvoltage:
- 28 V to 34 V
- protection type (overvoltage): shut down and latch off o/p voltage, re-power on to recover
- overheating:
- 100 °C ± 10 °C (RTH2)
- protection type (overheating): shut down and latch off o/p voltage, re-power on to recover
- environment:
- working temperature: -40 °C to +60 °C (refer to output load "derating curve")
- working humidity: 20 to 95 % RH non-condensing
- storage temperature, humidity: -40 °C to +80 °C, 10 to 95 % RH
- temperature coefficient: ± 0.03 % / °C (0 °C to 50 °C)
- vibration: 10 to 500 Hz, 5 G 12 min. / 1 cycle, period for 72 min. each along X, Y, Z axes
- safety & EMC:
- safety standards (Note 7): UL8750, EN61347-1, EN61347-2-13 independent (except for HLG-320H C type) approved ; design refers to UL60950-1, TUV EN60950-1
- withstand voltage: I/P-O/P: 3.75K VAC I/P-FG: 1.88K VAC O/P-FG: 0.5K VAC
- isolation resistance: I/P-O/P, I/P-FG, O/P-FG: 100M ohms / 500 VDC / 25 °C / 70 % RH
- EMI conduction & radiation: in compliance with EN55015, EN55022 (CISPR22) Class B
- harmonic current: in compliance with EN61000-3-2 Class C (= 50 % load) ; EN61000-3-3
- EMS immunity: in compliance with EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4K V), criteria A
- others:
- MTBF: 157.1K hrs min. MIL-HDBK-217F (25 °C)
- dimensions: 252 x 90 x 43.8 mm